Sensor
Content
If you followed the mentioned steps and still face the same issue, feel free to contact us under Contact
Status red / not connected
Should you notice that the sensor shows a red connection status in the portal or isn’t working as it should, you can try the following steps.
Make sure the sensor is turned on Switching on
Check the health (connectivity, battery) of the sensor in the portal
If your sensor is offline, try to reconnect it to your WiFi 4 - Connection to the Wi-Fi
If your sensor shows a low battery, check if it's still covered by warranty (mostly 2 years from registration date), and if yes, write to ROOMZ support. If no, contact your reseller to order a new battery
Connect the sensor with ROOMZ Tools and check the terminal for more information's ROOMZTools
Status grey / Battery 0V / last seen date 01.01.1970 in portal
If you forgot to switch on the sensor during the initial configuration, this error occurs. Please follow the steps below:
Open the sensor housing and turn the On/Off switch to “On” Switching on
Check on the ROOMZ Portal if the sensor is now connecting (connectivity green)
If not, rewrite the network configuration on the device 4 - Connection to the Wi-Fi
Connect to ROOMZTools and open the terminal for troubleshooting
Ghost-Meetings are not released (auto release)
The sensor receives its "action plan" with the last polling interval. If the meeting was created beforehand, the feature works. If the meeting was created after the last polling, the sensor has no information about it, and the feature does not work. E.g., when the polling interval is set to 2 hours, only the meetings created more than 2 hours before the meeting start will be known and will get released.
If you checked that but are still facing an error, follow these steps:
Check under Room option set if the function “Auto-Release” is enabled
Check if the sensor is associated with the right Room Link the devices
Check the health status of the sensor; if it's not green, continue with Sensor | Status grey / Battery 0V / last seen date 01.01.1970 in portal
Check in the https://roomzio.atlassian.net/wiki/spaces/SUP/pages/391839745/Basic#Workspace-reservation (Analytics) if there was a movement in the Room at that time, who disabled the function for that meeting
Check the position of the sensor, do a https://roomzio.atlassian.net/wiki/spaces/SUP/pages/282689574
Data is not shown in Analytics
Check the health status of the sensor; if it's not green, continue with Sensor | Status grey / Battery 0V / last seen date 01.01.1970 in portal
Control if the sensor is associated with the right Room Link the devices
Battery consumption too high
Contact ROOMZ Support to analyze the situation and get more information